Measurement date February 18, 2019 16:16:06 GMT
Experimenter Unknown
Participant X
Digitized points Not available
Good channels 47 EEG
Bad channels None
EOG channels Not available
ECG channels Not available
Sampling frequency 256.00 Hz
Highpass 0.00 Hz
Lowpass 128.00 Hz
Filenames sub-EPL31TWH0072_ses-V01SE06_task-full_rec-clip_run-01_clip-02_eeg.edf
Duration 07:52:48 (HH:MM:SS)
bids-validator@1.12.0
	1: [WARN] The recommended file /README is missing. See Section 03 (Modality agnostic files) of the BIDS specification. (code: 101 - README_FILE_MISSING)

	Please visit https://neurostars.org/search?q=README_FILE_MISSING for existing conversations about this issue.

        Summary:                  Available Tasks:        Available Modalities: 
        3596 Files, 3.31MB                                EEG                   
        129 - Subjects                                                          
        101 - Sessions                                                          


	If you have any questions, please post on https://neurostars.org/tags/bids.

  • Info: Test PASSED. All channels present on the channels.tsv file were found in the corresponding EDF file.
  • Info: Test PASSED. Units in the channels.tsv file match the units in the EDF file.
  • Info: Test PASSED. Filters defined in the channels.tsv match with the defined filters in the EDF file.
  • Info: Test PASSED. Sampling frequency in the files channels.tsv, EDF and json file match.
  • Info: Test PASSED. All electrodes positions in the electrodes.tsv file are numeric, as required by the BIDS standard.
  • Info: Assuming unipolar reference as the parameter 'iEEGReference' is not set to 'bipolar' in the json file.
  • Info: Test PASSED. All the contacts forming the channels in the channels.tsv and EDF files are present in the electrodes.tsv.
  • Warning: json file indicates that 2 EOG channels should be present but 0 EOG channels were found in the channels.tsv file.
  • Warning: json file indicates that 2 EMG channels should be present but 0 EMG channels were found in the channels.tsv file.
  • Warning: Length specified in the edf file (85104 seconds) doesn't seem to match the length indicated in the JSON file (23.64).
  • Warning: It seems that the JSON file is currently indicating the file length in hours, but the standard defines RecordingDuration in seconds.
Method infomax
Fit 264 iterations on epochs (7260160 samples)
ICA components 15
Available PCA components 23
Channel types eeg
ICA components marked for exclusion
ICA component topographies
Properties of Component 0
Properties of Component 1
Properties of Component 2
Properties of Component 3
Properties of Component 4